4
Required practical 4 · Electricity

I–V characteristics required practical

Aim: Plot I–V graphs for a filament lamp, a resistor at constant temperature and a diode.

Change (independent)Potential difference
Measure (dependent)Current
Keep the same (control)Component being tested, temperature (for the resistor)

Method

  1. Set up the component in series with an ammeter and a variable resistor, with a voltmeter across the component.
  2. Change the variable resistor to vary the p.d. and record V and I.
  3. Reverse the supply connections to get negative values.
  4. Repeat for each component.
  5. Plot current (y) against p.d. (x).

Kit list

  • Power supply
  • Variable resistor
  • Ammeter
  • Voltmeter
  • Filament lamp, resistor and diode
  • Protective resistor for the diode

Stay safe

The lamp gets hot. Don't touch it straight after use.

What the examiner asks

  • Resistor: straight line through the origin.
  • Lamp: an S-shaped curve, because resistance rises as the filament heats up.
  • Diode: current flows one way only, and only above a small p.d.
Aim for top marks

Going deeper

Key idea. Use a variable resistor (or variable power supply) to change the p.d. in steps; reverse the connections to get negative values.

Sample results

Sample results for a filament lamp

p.d. (V)Current (A)
0.00.00
1.00.10
2.00.17
3.00.22
4.00.26
5.00.29
6.00.32

Analysing the results

  • Plot current (y) against p.d. (x), including negative values from reversing the supply.
  • Resistor at constant temperature: a straight line through the origin (ohmic).
  • Filament lamp: an S-shaped curve; the gradient decreases because resistance increases as it heats up.
  • Diode: almost no current in reverse; current only flows above about 0.6 V forwards.
  • Calculate R = V ÷ I at a point to show how resistance changes (lamp: 10 Ω at 1 V, 18.8 Ω at 6 V).

Errors and how to reduce them

  • Systematic: the resistor heats up at higher currents. Keep the current low and switch off between readings.
  • Random: the lamp's reading drifts as it warms. Wait a few seconds for each reading to settle.
  • A protective resistor is needed in series with the diode to stop a large current damaging it.

Accuracy, precision and resolution

  • Take readings in equal steps and include negative values.
  • Repeat readings when increasing and decreasing the p.d.
  • Use more readings where the graph curves (e.g. around 0.6 V for a diode).
  • Resolution: use meters with suitable ranges.

Model 6-mark method

Read it, cover it, then try writing your own.

Show the model answer

Set up a circuit with a power supply, a variable resistor, an ammeter in series with the component, and a voltmeter in parallel across the component. Adjust the variable resistor to change the potential difference across the component, recording the current and p.d. for at least six values. Reverse the connections to the power supply and repeat to get negative values. Repeat each reading and calculate a mean. Plot current against potential difference. Repeat the experiment for a resistor at constant temperature, a filament lamp and a diode (with a protective resistor in series). Hazard: the lamp gets hot; switch off between readings.

Grade 7–9 extras

  • Explain the lamp's curve using particles: as the filament gets hotter, its ions vibrate more, electrons collide more often, so resistance increases.
  • Explain why the resistor line is straight only at constant temperature (ohmic conductor).
  • Identify the threshold p.d. of the diode from the graph.

Common mistakes

  • Plotting the axes the wrong way round (AQA uses current on the y-axis).
  • Joining points dot-to-dot instead of drawing a smooth curve.
  • Forgetting the negative half of the graph.

Practise the write-up